Averis Labs

Assess, monitor, maintain, replace

A battery is only as reliable as the system watching it. We look after the whole UPS fleet, not just the next battery order.

  1. Assess

    Model, load, runtime, battery age, self-test and fault history for every UPS, in a written report.

  2. Monitor

    SNMP monitoring of every UPS, with alerts on power events, low battery, overload or high temperature.

  3. Maintain

    Scheduled health checks and reports, so battery condition is a trend you can see, not a surprise.

  4. Replace

    Planned replacement with EnerRocket batteries, sized to your UPS, before a failed cell causes an outage.

UPS monitoring, run by us or by your team

Live telemetry from any SNMP UPS: voltage, load, charge, temperature, runtime, self-test and fault status, across Vertiv, Schneider Electric and APC, Eaton, Riello, ABB and Delta fleets.

Managed service

We run the dashboard and alerting on a monthly engagement. Your team gets the alerts; we handle the platform and the follow-up.

One-time deployment

We design, install and configure the monitoring stack, hand it over documented, and your team runs it from there.

EnerRocket batteries

A Global Power Source brand in operation since 1988, used by organizations including HSBC, Oracle, Cisco and IBM. Averis Labs is an authorized Philippine supplier, and sizes every string to your UPS as part of the assessment.

  • UL
  • CE
  • IEC 60896
  • ISO 9001
Design life
12 years
Warranty
5 years
Range
5 to 200 Ah, 12 V
Construction
Sealed AGM/VRLA, 99.99% virgin lead, flame-retardant ABS
EnerRocket ES and ESC series we deploy and monitor
ModelVoltageCapacityTypical application
ES 5-1212 V5 AhSmall UPS, alarm and security panels
ES 7-1212 V7 AhUPS, security, medical devices
ES 9-1212 V9 AhUPS, telecom, access control
ES 18-1212 V18 AhTelecom, solar, compact backup
ES 26-1212 V26 AhMid-size UPS, telecom sites
ES 33-1212 V33 AhUPS strings, industrial control
ES 40-1212 V40 AhTelecom, data and signaling
ES 65-1212 V65 AhLarge UPS, telecom back-up
ES 75-1212 V75 AhData-center battery strings
ESC 100-1212 V100 AhCritical backup, telecom hubs
ESC 200-1212 V200 AhHigh-capacity data-center systems

High-rate ESH (watt-rated) UPS series and flame-retardant (FR) variants are available on request.

Where it matters

  • Server rooms and data centers

    Battery strings from single UPS units to full UPS rooms.

  • Telecom and network closets

    Sites that have to stay up between visits.

  • Fire alarm and security panels

    Life-safety and access control, where a flat battery is a compliance failure.

  • Medical equipment

    Clinical devices and facility systems that cannot tolerate a transfer gap.

Questions we are asked

What is included in a UPS health assessment?

We record each UPS model, load, runtime and battery age, review its self-test and fault history, and check battery condition. You get a written report with what needs attention now and what can wait.

Does Averis Labs monitor UPS systems remotely?

Yes. We monitor UPS systems over SNMP with live telemetry, alerts on power events, low battery, overload or high temperature, and battery replacement forecasting, as a managed monthly service or a one-time deployment your own team runs.

Which UPS brands can you monitor?

Any UPS with an SNMP card, including Vertiv, Schneider Electric and APC, Eaton, Riello, ABB and Delta.

What is EnerRocket?

EnerRocket is a Global Power Source battery brand, in operation since 1988, producing sealed lead-acid (AGM/VRLA) batteries for UPS systems, telecommunications, fire and security panels and medical equipment. Averis Labs is an authorized Philippine supplier.

What is the design life and warranty of EnerRocket batteries?

EnerRocket ES and ESC batteries carry a 12-year design life and a 5-year warranty, and are certified to UL, CE, IEC 60896 and ISO 9001.

How do I start?

Send your UPS make and model, the number of batteries or strings and the number of sites to hello@averislabs.com.ph or call +63 976 232 1108. We reply within one business day to schedule an assessment.

Not sure how healthy your UPS batteries are?

Send us your UPS make and model, battery count and number of sites. We will schedule an assessment within one business day.

Request a UPS health assessment
Phone
+63 976 232 1108
Email
hello@averislabs.com.ph
Office
Level 6, Ayala Triangle Gardens Tower 2, Makati City
Reply